Improvements
- Make guide assembly E1140/E1332 turnable and allow flipping of E1332 component within assembly. [RM-14775]
- Display Materials in Material Option Menu of BOM in upper case by default. [RM-14757]
- Also display post regeneration relations in component dialog relation field. [RM-14751]
Bugfixes
- Issue fixed: Cooling UDFs have invalid extra surface at the cosmetic thread due to invalid definition [RM-14781]
- Issue fixed: Can not select plate F53 in Drawing Area of Moldbase Definition. [RM-14597]
- Issue fixed: Invalid LG2 value in blade ejectors EJP-EHNB and EJP-ELHB from DME. [RM-14628]
- Issue fixed: 'Archive Instance' does not work in case components folder has no write access. [RM-14617]
15.0.1.3
Improvements
- Meusburger Support Pillar E1513 needs option to create a flat blind hole in last cut out model. [RM-10022]
- So far only the EMX_SURFACE_FUNCTION parameter is transfered from library cut quilts to the resulting cut out surface. Now also all other string, integer, double and boolean parameters are transfered. [RM-13048]
- Add option for screws to allow cuting in previous plate. [RM-8037]
Bugfixes
- Issue fixed: In case library components are asssembled in a loop the cut quilt cut outs are not created. [RM-14546]
- Issue fixed: In UDF screw_cb_coax the CB_DEPTH dimension and CD_DEPTH_OPPOSITE dimension are flipped. [RM-14517]
- Issue fixed: Spaces in configuration paths are not considered anymore. [RM-14568]
15.0.1.2
Improvements
- Simplify assembly logic for Meusburger E1330 [RM-14475]
Bugfixes
- Issue fixed: EMX_SURFACE_FUNCTION parameter are not on both sides of holes in the plate templates [RM-13600]
- Issue fixed: auto_libtread, quilt_cut udfs etc. are not found in case udf folder exists in custom configuration, but udf is only available in installation [RM-14468]
- Issue fixed: Always paint mold base drawing area in case of editing nominal values, otherwise offset is not updated correctly [RM-14466]
- Issue fixed: Invalid orientation of rotation fixture for ejector sleeve templates [RM-14476]
- Issue fixed: In Modify Mode References get lost when changing type with different reference group type or are overwritten by Moldbase Default references [RM-10699]
15.0.1.1
Improvements
- Introduce new Option EXCEL_TEMPLATE_PATH. In case Excel file is Read-Only create copy in current working directory based on BOM_FILENAME option. [RM-14386]
- Improve the Library Component Editor. [RM-14329]
- EMX_BOM_INFO of sub components cannot be edited in Library Component Dialog. Manual changes in dat file get lost. Introduce new Source column to edited. Local Part Name entries. [RM-11390]
Bugfixes
- Issue fixed: In case no size files exist in config plates supplier the size is not set up correctly in moldbase definition modify mode [RM-14450]
- Issued fixed: First cut in face owner does not work anymore for cooling plugs. Introduce variable option ADD_CUT_IN_FACE_OWNER in sealing plugs. [RM-14377]
- Issued fixed: Automatic screw length calculation for socket flat head screws MEUSBURGER E1220 does not work as expected. [RM-10738]
15.0.1.0
Bugfixes
- Issue fixed: Options in user document folder for EMX 15.0.0.0 are referencing the EMX 14.0.0.0 configurations and settings. [RM-14277] [SPR-14073229]
- Issue fixed: Instances and ordering numbers in WEMA S3113 file with diameter bigger and equal 12 are invalid. [RM-14261]
15.0.0.1
Enhancements
- Update MEUSBURGER catalog to July 2022 status.
Bugfixes
- Issue fixed: HASCO core retainer plates can not be selected. [RM-14001]