IFX Changelog
11.0.3.0
Bugfixes
- If an error occurred when updating the hole positions, the entire update process was stopped. The position of some holes was not updated. The update process is now no longer aborted even if an error occurs. [RM-18225]
- When creating auxiliary geometry, an attempt was made to create a reference pattern, although the reference used was not patterned. The pattern behavior of the auxiliary geometry has been revised. [RM-18731][SPR-15728713]
- After the hole has been created, the hole note is reset to ensure that it is displayed correctly. [RM-18070]
11.0.2.0
Enhancements
- Creo 11.0.2.0 ready version.
11.0.1.0
Enhancements
- Ignore readonly state of model for affected APIs (2nd. List). [RM-17663]
- Align clearance holes for bolts and screws to DIN EN 20 273. [RM-13634]
- If the configuration files 'ifx_*_data.cfg' are not found in the custom configuration folder, the files are loaded from the IFX installation. [RM-16524]
- Added new model unit parameters to allowable model parameters. These new 'PTC_UNITS_*' parameters are introduced in Creo 11.0. [RM-17172]
- Insert the diameter 'Medium Fit' for inch clearance holes if the value 'MED_DEC' from the hole chart (*.hol) is greater than zero. [RM-16284]
Bugfixes
- Problems with translations longer than 80 characters have been fixed. [RM-17580][SPR-15260736]
- Change fastener parameter. [RM-17203]
→ ISO 7045 changed to pan head screw
→ ISO 7380 changed to button head screw
- After resetting the hole note, the dimensions are replaced again. [RM-17179]
11.0.0.0
Enhancements
- Creo 11.0 ready version.
- IFX is not supported in Creo+ collaboration mode. The commands are disabled. [RM-16578][SPR-14889104]
- Rework validation for configuration folder. [RM-16419]
- Ignore readonly state of model for affected APIs. [RM-16326]
- Before changes are made, a check is done to see if a model is read-only. If this is the case, a conflict dialog is displayed. The user must unlock the model for changes. [RM-15899][SPR-14624197][SPR-14592374]
- Verify library files part 1. [RM-14909][RM-15865][SPR-14387616][SPR-14673710]
→ Verify if files exists.
→ Verify section 1 of fastener data files.
→ Still open: Verification of section 2 of fastener data files.
- Add new screw option COUNTERSINK_HOLE_USE_LIMITS. [RM-15262][RM-15400][SPR-14504539][SPR-14536820]
- Use API 'ProElementHole*Set()' to set the thread series and the screw size by value. If the value (i.e. M10x1.5) does not exist, an exception is thrown. In the past the thread series and the screw size where set by index. If the index was wrong, creo crashes immediately. [RM-15348]
- Ignore values (e.g. tabs and spaces) behind 'THREAD_DATA' in hole charts. [RM-15215]
- Before retrieving, check if a fastener exists to avoid the message: 'fastener-mdl' cannot be retrieved.
If the fastener model does not yet exist, create it using the template. [RM-14618]
Improvements
- Output ifx.log to <personal>\buw\IFX\logs\<version>. [RM-16128]
Bugfixes
- If the personal folder cannot be determined, the ifx.log will be written to the current working directory. If the working directory cannot be determined either, logging will be disabled. [RM-16320][SPR-14842569]
- A message that was too long caused a crash. [RM-16121][SPR-14797981]
- If the library location is set to 'Windchill', the library directories will be created if they do not exist. [RM-15919][SPR-14683389]
- Only accept cylindrical surfaces as multi-reference. [RM-15199]
- Consider hole charts in working directory. [RM-14899][SPR-14386755]
- Solved problem for screw-in fasteners. Offset (depth) was set to '-0.1'. [RM-14871]
- Parameter values for the 'BUW_*_ID*' fastener component parameters were set to '0' during redefinition. [RM-11509]