Changelog
4.0 M140 2020-07-20-01
Improvements
- Release for Creo Parametric P-30-55.
Bugfixes
- Fix the 31 character limit for file name. [RM-9677][SPR-10054607]
4.0 M120 2019-11-11-01
Improvements
- Release for Creo Parametric P-30-53.
4.0 M110 2019-08-08-01
Improvements
- Release for Creo Parametric P-30-52.
4.0 M100 2019-05-08-01
Improvements
- Release for Creo Parametric P-30-51.
4.0 M090 2019-02-11-01
Improvements
- Release for Creo Parametric P-30-50.
4.0 M061 2018-09-21-01
Bugfixes
- Fix problem with configuration dialog. Unlock sc.dll to avoid problem.
4.0 M060 2018-06-06-01
Improvements
- Ignore comments while using the Instance Creator. All lines with "!" are ignored. [RM-5889]
Bugfixes
- While converting the library only *.prt files are copied to the designation folder. All versions like *.prt.1 were ignored. [RM-5856]
- The inserts pulldown was too small. [RM-6542][C14142706]
- Special characters in the *.dat an *.txt files (like ÄÖÜ) where shown incorrectly. [RM-6543]
4.0 M050 2018-01-22-01
Improvements
- Version for Creo Parametric 4.0 M050
4.0 M041 2018-01-18-01
Bugfixes
- If not the leader of a multi-reference pattern is selected, the process is canceled. [RM-5855]
- Reset of [RM-5560] because of regression test failure. Rework this feature in next release. [RM-5867]
4.0 M040 2017-12-13-01
Enhancements
- Reuse axis from hole features to avoid creation of a new axis. [RM-4877]
- While reassemble the hole diameter is checked. Only cylinders which are bigger then the fastener diameter are accepted. [RM-4935]
- No you can group your fasteners in the option menus. [RM-5416] [RM-1677]
Bugfixes
- Thread length is not correct while reassemble. [RM-4784]
- Layers are created without set in configuration dialog. [RM4785]
- Cannot modify license.ini after IFX start. [RM-5407]
- Fix problem with hole creation. If the hole depth or thread depth is the same as the plate thickness, the hole is set to thru hole or full thread. [RM-5560]
- Fix gab in preview. [SPR-6971252]
4.0 M030 2017-07-06-01
Bugfixes
- Some fasteners shows wrong PTC_CONDITION. [RM-4995]
- The placement reference of a component of IFX will be missing after redefining. [SPR-SPR6703005]
- In configuration dialog the library path string lengths is restricted to 32 characters. [RM-5180]
4.0 M014 2017-04-21-01
Bugfixes
- Fix problems with AFX FL license. Reread options if floating license is requested. [RM4872]
- Rework license release for AFX FL and IFX LL. [RM-4879]
- Intelligent Fastener commands does not appear proper in Tools tab ribbon. Also Creo Advanced Framework command is added in Tools tab. [SPR-6589560]
4.0 M013 2017-03-27-09
Enhancements
- Use the environment variable IFX_STARTUP set to NO to start without IFX. [RM-1370]
- Select RMB on a group or a patter with a fastener to access the IFX commands. [RM-4224]
- Select a group or a pattern with a fastener to reassemble it is now possible. In the past always the fastener must be selected. [RM-4224]
- If an axis is selected as position reference, allow only those placement surfaces which are normal to this surface (within a small angle limit). [RM-4242]
- In the Select Reference dialog the loop now always starts as soon as you click a collector. [RM-4243]
- Add a new layer concept. Add new keywords to the ifx_start_mdl.cfg file:
RENAME_LAYER
, DELETE_LAYER
, RULE_LAYER_TEMPLATE
and CREATE_RULE_LAYER_PARAM
. [RM-4788]
- While reassemble the OK and the Cancel buttons are disabled. Select a different placement reference to enable the buttons. [RM-4825]
- Show preview in graphic window by default. [RM-4826]
Bugfixes
- Fix problem with wrong colors in the fastener dialogs. [RM-4831]
- Fix performance problem in the option menus. [RM-4838]
4.0 M011 2017-01-24-01
Improvements
- Main release. First official B&W version.