SMARTElectrode Changelog
19.4.2.0
Enhancements
- Allow usage of electrode parameters in placeholders of position sheets. Placeholders are checked for assembly parameters in the first step.
Available electrode parameters will be checked in second step. If parameters with same default (for example "&partname") are used for assembly and electrode,
the parameter name must be used instead of the rule to display the electrode parameter. [RM-25773]
- Provide German online help.
[RM-23874]
Improvements
- Drawing creation: copy views from positioning sheet to electrode sheet instead of moving views by mapkey.
This change takes effect if option MERGE_EDM_POSITIONING_SHEETS=3 (Add positioning sheets to electrode drawing) is set.
[RM-25868]
- Ask user to update operation files in configuration, when importing older configuration to version 19.
[RM-25811]
Bugfixes
- Correct insert location and grow direction for drawing tables.
- Base UI: avoid transient state warning when closing Base user interface with applied electrode holder.
Necessary preconditions that lead to the occurrence of the issue:
1. working in active workspace
2. Creo option dm_upload_objects = automatic is set
3. Creo session without advanced assembly extension
[RM-25868]
- Drawing creation: prevent crash during drawing creation if a default layer model for drawings is set by Creo option DEFAULT_LAYER_MODEL.
[RM-25586]
- Windchill: fix transient state issue when Creo option dm_upload_objects = automatic is set and drawing views are moved from position drawing to electrode drawing.
[RM-25867]
- Fix exception error which appears in some edge cases when loading template models from Windchill.
[RM-25574]
- Operation Cosmetic: cleanup relations in electrode assembly after definition of new origin to avoid relation error message in Creo 13 for outdated UDF's.
[RM-25666]
- Operation Cosmetic: remove outdated relations from UDF's for operation highlight to avoid relation error message in Creo 13.
[RM-25667]
- Base: update definition of chamfers applied to base. Use two adjacent surfaces as references instead of edge. The reason for the update is
the potential change of the reference's geometry ID when the size of the base is modified. Revision of edge ID may lead to a warning or error
if "Outdated placement or feature" is set in Creo Notification Center "Reference notifications".
[RM-25012]
19.4.1.0
Enhancements
- Export: allow creation of combined export. Multiple exports can be written at the same time.
Use new keyword "SE_INSERT:" followed by export name (=directory name). Example:
#SE_INSERT:IGES#
#SE_INSERT:STEP#
The complete output is redirected to the combined file by default. Use option "SE_OUTPUT_TO_FILE YES"
in configuration of sub-export to generate the output in a separate file.
[RM-25086]
Bugfixes
- Drawing: move views of position sheet correctly to combined electrode sheet if added to main drawing.
[RM-25169]
- Drawings: make sure creation of drawings does not stop during processing.
If drawing creations stops midway, call command "Internal use only" in SMARTElectrode ribbon > group help > overflow. [RM-25158]
- Export: make sure items listed in option SE_EDM_DISPLAY_LAYERS are correctly added to layer SE_EXPORT_DISPLAYED.
New items are automatically removed from layer SE_EXPORT_HIDDEN if necessary.
Delete layers SE_EXPORT_DISPLAYED and SE_EXPORT_HIDDEN manually or use option SE_EDM_RESET_LAYERS=YES to enforce reset.
[RM-25131]
- Drawings: fix dimension creation workflow. Avoid duplicated dimensions on electrode part drawing.
Make sure to create missing dimensions when positioning sheet for electrode is updated.
[RM-24961]
19.4.0.0
Enhancements
- Add support of Creo 13.0.0.0.